QAmcp
GitHub

Directory / SparkQuote NEC calculators

SparkQuote NEC calculators

by sparkquote.ai · https://sparkquote.ai/mcp

NEC 2023 electrical calculators: wire size, ampacity, voltage drop, conduit fill, box fill, load.

10 tools✓ all read-only✓ no account neededPricing: on their site
See pricing →Visit website
80 /100
FAIL

10 of 10 checks · 18 Oct 2026

Is SparkQuote NEC calculators MCP server safe?

A test can only see what the server shows from outside, not what it does with your data behind the scenes. Connect servers from makers you trust.

What it can do

10 tools, in the server's own words.

wire_sizeread-only

Minimum conductor size for a circuit: NEC Table 310.16 ampacity at the termination temperature rating, the 240.4(D) small-conductor limits, voltage drop over t…

voltage_dropread-only

Voltage drop for a given conductor size, current and one-way length, single- or three-phase, from NEC Chapter 9 Table 8 circular mils (VD = 2·K·I·L / CM, or √3…

watts_to_ampsread-only

Current drawn by a load in watts at a voltage and power factor, single- or three-phase, plus the 125% continuous-load value.

conduit_fillread-only

Percent fill and maximum number of THHN/THWN-2 conductors of one size in EMT or PVC Schedule 40, from NEC Chapter 9 Tables 1, 4 and 5.

box_fillread-only

Minimum outlet box volume from NEC 314.16(B): conductor, device (2 each), clamp and grounding allowances times the Table 314.16(B) volume for the largest condu…

load_calculatorread-only

Dwelling service load by the NEC 220.82 optional method: 3 VA/ft² lighting, small-appliance and laundry circuits, fixed appliances, demand factor, heating or c…

ohms_lawread-only

Ohm's law and power: give exactly two of voltage, current, resistance and power; the other two are calculated.

panel_scheduleread-only

Lays circuits out on a 120/240 V single-phase or 208Y/120 V three-phase panel and totals the load per phase with the imbalance.

bid_calculatorread-only

Electrical bid price from materials, markup, labor hours and rate, job costs, overhead and a target net margin (price = break-even / (1 − margin)).

nec_ampacityread-only

Allowable ampacity of one insulated conductor from NEC Table 310.16 (not more than three current-carrying conductors in a raceway or cable, 30°C ambient), befo…

Test results

Safe mode: only tools labeled read-only were run. How the test works

Test it yourself

Free and open source. Same checks, same score.

npx qamcp-cli https://sparkquote.ai/mcp

Score over time

Reviews

Coming soon: reviews from people who use SparkQuote NEC calculators, signed in with GitHub, one per person. Reviews never change the score.

Is this your server?

Soon you can claim this page: re-test it from here, reply to results, and show a "Tested by QAmcp" badge.

Have a concern, or want it removed? Ask us and we'll take it off the list. How the directory works